BMS Kit

X2 BMS is compatible to connect Victron Multi directly and will isolate when system is off or event of LVP. X2 BMS is also compatible with all alternator controllers by the unique pre-disconnect – AFD output. No CAN is needed and makes the system safer from electrical disturbance (EMI) as well as safer protection in event of LVP. Connection of Victron Multi or Alternator control require a €10 signal relay.

The following features are included in the X2 BMS and do not have to be purchased separately:

Isolater, Cyrix-relay, DC/DC, Alt.-B device, Regulator to control the alternator, Charger with Lithium-profile, Pre-charge devices, CAN-cables, GXCC / GX device as interface for CAN-bus, Firmware / PC-cable to program BMS settings, Device for pulse control bi-stable relay.

BMS Kit-1 / 12V

Kit-1 / 12 V includes:

  • X2 BMS 12/24
  • BMS Control
  • Cable to BMS Control, 3 – 8 meter (custom length) connected to Phoenix terminal block
  • Fuse box (8) pre-assembled / wired and plug to X2 BMS of fused cell-connection. Power connection and to power resistor.
  • Pre-charge power resistor 5 Ohm
  • ATM fuses and screws (A4)

BMS Kit-2 / 12V

Kit-2 / 12 V includes:

  • X2 BMS 12/24
  • BMS Control
  • Cable to BMS Control, 3 – 8 meter (custom length) connected to Phoenix terminal block
  • Fuse box (8) pre-assembled / wired and plug to X2 BMS of fused cell-connection. Power connection and to power resistor.
  • ATM fuses and screws (A4)
  • Tap wires 5 pcs 2 – 4 m / 8 mm or 4 / 6 mm terminal (custom)
  • DC Charge Relay, Gigavac 12/24 non-latching, 500+ A
  • DC Load Relay, Gigavac 12/24 non-latching, 500+ A
  • Busbar to connect relays (tailor-made in tinned copper)
  • Pre-charge power resistor 5 Ohm

BMS Kit-2-BS / 12V

Kit-2-BS / 12 V includes bi-stable relay*

  • X2 BMS 12/24
  • BMS Control
  • Cable to BMS Control, 3 – 8 meter (custom length) connected to Phoenix terminal block
  • Fuse box (8) pre-assembled / wired and plug to X2 BMS of fused cell-connection. Power connection and to power resistor.
  • ATM fuses and screws (A4)
  • Tap wires 5 pcs 2 – 4 m / 8 mm or 4 / 6 mm terminal (custom)
  • DC Charge Relay, Gigavac 12/24 non-latching, 500+ A
  • DC Load Relay, Gigavac 12 V latching relay (bi-stable), 500+ A
  • Busbar to connect relays (tailor-made in tinned copper)
  • Pre-charge power resistor 5 Ohm

*) Note, X2 BMS will disconnect Charge Relay during discharging i.e. this relay do not need to be bi-stable.

BMS Kit-1 / 24V

Kit-1 / 24 V includes:

  • X2 BMS 12/24
  • BMS Control
  • Cable to BMS Control, 3 – 8 meter (custom length) connected to Phoenix terminal block
  • Fuse box (12) pre-assembled / wired and plug to X2 BMS of fused cell-connection. Power connection and to power resistor.
  • ATM fuses and screws (A4)

BMS Kit-2 / 24V

Kit-2 / 24 V includes:

  • X2 BMS 12/24
  • BMS Control
  • Cable to BMS Control, 3 – 8 meter (custom length) connected to Phoenix terminal block
  • Fuse box (12) pre-assembled / wired and plug to BMS of fused cell-connection. Power connection and to power resistor
  • ATM fuses and screws (A4)
  • Tap wires 9 pcs 2 – 4 m / 8 mm or 4 / 6 mm terminal (custom)
  • DC Charge Relay, Gigavac 12/24 non-latching, 500+ A
  • DC Load Relay, Gigavac 12/24 non-latching, 500+ A
  • Busbar to connect relays (tailor-made in tinned copper)
  • Pre-charge power resistor 10 Ohm

BMS Kit-2-BS / 24V

Kit-2-BS / 24 V includes bi-stable relay*

  • X2 BMS 12/24
  • BMS Control
  • Cable to BMS Control, 3 – 8 meter (custom length) connected to Phoenix terminal block
  • Fuse box (12) pre-assembled / wired and plug to X2 BMS of fused cell-connection. Power connection and to power resistor.
  • ATM fuses and screws (A4)
  • Tap wires 9 pcs 2 – 4 m / 8 mm or 4 / 6 mm terminal (custom)
  • DC Charge Relay, Gigavac 12/24 non-latching, 500+ A
  • DC Load Relay, Gigavac 24 V latching (bi-stable), 500+ A
  • Busbar to connect relays (tailor-made in tinned copper)
  • Pre-charge power resistor 10 Ohm

*) Note, X2 BMS will disconnect Charge Relay during discharging i.e. this relay do not need to be bi-stable.

Options

  • Signal relay 12 V (1.0 W Coil power) incl. terminals:   €10
  • Signal relay 24 V (1.0 W Coil power) incl. terminals:  €10
  • Busbar 4x 10 mm studs, tinned copper bus 8x30x150 mm >500A.   €55
  • Fusebox with cover + ANL fuse 500 A (or 400 / 300 A) 12/24 V.   €38
  • Switch 0-1-Combine, Blue Sea Systems, m-series.  €52
  •  
  • Victron Battery Protect BP220 12/24 V.  €87
  • Victron Battery Protect BP100 12/24 V.  €47
  • Victron Argofet 1:2  200A Isolater.  €147
  • Victron Argofet 1:3  200A Isolater.  €176
  • Victron Argodiod 1:2  160A Isolater.  €109

Images coming soon…